Definition

Amplitude is the displacement of a vibrating component from its reference position. Suppliers may specify single amplitude or peak-to-peak displacement, and the convention must be confirmed before comparing readings.

Frequency is the number of vibration cycles per unit time. It is determined primarily by the drive speed and the exciter configuration.

Amplitude drop in this context means a measured reduction in displacement compared with the machine's baseline, after confirming that the measurement method is consistent.

Working Principle

Amplitude is the result of a complete dynamic system. The motor and transmission supply speed to the exciter. The exciter generates periodic force. The screen body, supports and material load determine the resulting motion.

Drive speed. A motor running below its rated speed, a VFD set below the specified frequency, or an electrical supply problem all reduce the speed reaching the exciter. Because force scales with the square of speed, a modest speed reduction produces a disproportionate force reduction.

Transmission. Belts, pulleys, couplings, shafts and keys carry the power from motor to exciter. Slip at any of these points reduces exciter speed even when motor speed is correct. Belt slip is the most common single cause of reduced amplitude on belt-driven screens.

Exciter. Eccentric weights, bearings, gears and lubrication determine the force generated at a given speed. Weight position, locking, condition and assembly all affect output. Internal wear produces resistance, noise and heat.

Structure. Screen body mass, stiffness, joints and support arrangement determine how force becomes motion. Cracks, loose fasteners, damaged springs and foundation problems change the response without changing the force generated.

Load. Material adds effective mass to the system. Excessive feed, uneven distribution, wet material, blockage and accumulation increase the load beyond the design condition and reduce the observed motion.

Benefits

  • Correct diagnosis first time, avoiding replacement of serviceable motors and exciters.

  • Lower repair cost when the fault is identified at the cheapest point in the system.

  • Reduced downtime when the actual cause is found quickly.

  • Structural protection when excessive vibration is avoided rather than created by trial adjustments.

  • Better spare parts planning when failure modes and consumption rates are recorded.

  • Reliable trending when baseline measurements are established and maintained.

Applications

  • Large mining screens in iron ore, copper ore, gold ore and base metal circuits.

  • Aggregate processing screens operating continuously under abrasive duty.

  • Coal preparation where wet screening and variable feed apply.

  • Belt-driven screens where transmission slip is a frequent cause of reduced amplitude.

  • Direct-coupled and vibration motor installations where motor and coupling condition are primary.

  • Dual-motor linear screens where weight configuration and synchronization are critical.

These duties sit between size reduction in CRUSHING and downstream CLASSIFICATION or DEWATERING. Amplitude reduction propagates as mis-sized feed into the next stage.

Material Comparison



Property Drive Speed Fault Transmission Fault Exciter Fault Structure or Load Fault
Frequency Reduced Reduced Normal or unstable Normal
Amplitude Reduced at all points Reduced at all points Reduced, possibly uneven Reduced or uneven
Detection Electrical measurement Speed comparison, belt inspection Bearing temperature, weight position Amplitude mapping, structural inspection
Repair cost Moderate Low Moderate to high Low to moderate
Risk if misdiagnosed Replacing motor unnecessarily Replacing exciter unnecessarily Adjusting weights without approval Compensating with increased force

Application Comparison



Scenario Dominant Symptom Diagnostic Priority
Amplitude and frequency both reduced Speed loss Motor supply, VFD, belt slip
Frequency normal, amplitude reduced Force or response loss Weights, bearings, structure
Amplitude reduced on one side Asymmetry Springs, structure, dual-motor synchronization
Amplitude normal, throughput reduced Process issue Feed distribution, blinding, aperture
Recent maintenance preceded the change Configuration change Verify weights, belts, fasteners against drawing
Sudden change during operation Component failure Transmission, bearing, structural failure

Industry Application Matrix



Industry Typical Drive Common Amplitude Drop Cause Diagnostic Priority
Iron ore Belt-driven large frame Belt slip Belt condition and tension
Copper Belt or direct-coupled Coupling wear, bearing wear Coupling and bearing inspection
Gold Multi-motor linear Weight configuration mismatch Weight position, rotation direction
Coal Belt-driven sealed units Contamination, belt slip Sealing, belt condition
Aggregates Belt-driven Belt tension, spring degradation Belt and spring inspection
Sand and gravel Vibration motors Motor supply, bearing wear Electrical and bearing check
Industrial minerals Belt or direct Bearing damage, misalignment Bearing and alignment
Base metals Heavy-duty belt-driven Belt failure, structural movement Belt and structural inspection
Phosphate Sealed belt-driven Corrosion-related electrical fault Electrical and sealing
Tailings Dewatering screens Belt slip, spring condition Belt and support inspection

Selection Guide

1. Confirm the measurement. Single or peak-to-peak. Same instrument, same points, same orientation, same operating condition as baseline.

2. Record frequency and operating speed. Screen vibration frequency, motor speed and exciter speed where accessible. Compare with approved values.

3. Review the process condition. Feed rate, distribution, moisture, particle size, deck loading, recent production changes.

4. Check the electrical and motor system. Qualified personnel inspect supply, motor condition, current, VFD settings.

5. Inspect the transmission.