logo
Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
TOGETHER HTL LTD
Home News

Self-Cleaning Overband Magnet vs Metal Detector + Diverter — Which Is Better for Crusher Protection?

TOGETHER HTL LTD is a very good company , I am very willing to cooperate with you, safe, efficient, professional, honest, happy! Thank you for providing me with stable service and products. -----EUROPAT

—— EUROPT INDUSTRIAL

I'm Online Chat Now
Company News
Self-Cleaning Overband Magnet vs Metal Detector + Diverter — Which Is Better for Crusher Protection?
Latest company news about Self-Cleaning Overband Magnet vs Metal Detector + Diverter — Which Is Better for Crusher Protection?

Key Takeaways

· Magnets remove; detectors detect. A detector + diverter is the only layer that can catch non-ferrous and manganese steel tramp metal.

· Capture depth, not catalogue pull force, decides what a magnet gets: burden depth, belt speed, suspension height and how the metal presents itself.

· Every detector alarm costs production — sequencing the magnet upstream is what keeps the final gate trusted and switched on.

· A diverter flap converts alarms into a reject stream with near-zero downtime, trading a small volume of saleable material for uninterrupted crushing.

· Steel-cord belts, metal clip splices and magnetite ores all impose hard limits on detector performance and must be specified up front.

· One uncrushable object through a cone crusher routinely costs more than the installed price of a detector and diverter.

Summary Table

Criterion

Self-Cleaning Overband Magnet

Metal Detector + Diverter

Detects

Ferrous only (ferromagnetic)

All metals: ferrous, non-ferrous, stainless, manganese steel

Removes metal

Yes — lifts it off the belt automatically

No — signals; diverter or stop does the work

Metal must be

Exposed or near the burden surface

Anywhere in the burden, including buried

Blind spots

Non-ferrous, manganese steel, deeply buried pieces

Pieces below the aperture/speed sensitivity limit; steel-cord belts (conventional coils)

Cost when it acts

Almost none — no belt stop

A reject volume (diverter) or a belt stop (no diverter)

Main cost driver

Field depth at the metal's position vs belt speed

Aperture size, belt type, test discipline

Best role

Bulk ferrous reduction, first line of defence

Final gate immediately before the crusher

latest company news about Self-Cleaning Overband Magnet vs Metal Detector + Diverter — Which Is Better for Crusher Protection?  0

Why the Sequence "Magnet First, Detector + Diverter Last" Wins in Real Plants

The order is not tradition — it follows from how the two devices fail.

The magnet handles volume; the detector handles exceptions. If an electromagnetic unit lifts an excavator tooth before the detector ever sees it, you avoid a belt stop for a piece that was going to be removed anyway. Fewer alarms means the detector stays trusted and switched on — and a detector that is switched off protects nothing. Field data from two-layer installations consistently shows nuisance-trip reductions of 60–80% once a properly sized magnet works the upstream belt.

The detector catches what the magnet physically cannot. Manganese steel hammers and liners, stainless fittings, non-ferrous scrap and deeply buried metal are not overlap — they are the detector's exclusive territory. That is why the detector belongs at the last practical point before the crusher: it is the final device that can still act before damage occurs.

The diverter is what makes the final gate economically viable. Without one, every alarm means a stopped belt, an operator walk-out, and a hunt for a bolt somewhere in hundreds of tonnes of product. With a flap diverter, the alarm becomes a split-second rejection of a small side stream. Plants pay for that reject volume in saleable material, but they stop paying in crushing downtime — and the arithmetic strongly favours the trade at any reasonable tonnage.

Position details decide whether the theory works:

· Mount the magnet on the upstream transfer where the burden is shallowest and most stable.

· Install the detector immediately upstream of the crusher feed, with enough free belt distance after the detector to accommodate the stopping distance calculated from belt speed and brake time.

· Keep the detector zone clean of steelwork, use non-metallic idlers where the manufacturer requires them, and record splice positions in the control logic.

· Give the magnet's discharge chute a locked, spill-proof collection point so captured iron cannot re-enter the product route.

· Add mechanical backstops — an impact bed under the loading point and clean transfer chutes — because a protection layer is not a substitute for a well-fed belt. A stable burden profile, supported by an appropriate Heavy-Duty Conveyor Impact Bed, makes both the magnet's capture window and the detector's test results meaningful.

latest company news about Self-Cleaning Overband Magnet vs Metal Detector + Diverter — Which Is Better for Crusher Protection?  1

Contact Us

Contact: Annie Lu

Email: annie.lu@huataogroup.com

Phone / WhatsApp: +86 180 3242 2676

Website: http://www.tufflexscreen.com

We warmly welcome customers from around the world to contact us and establish mutually beneficial partnerships.

Pub Time : 2026-11-23 09:37:45 >> News list
Contact Details
TOGETHER HTL LTD

Contact Person: Mr. Maple

Tel: +86 17778255675

Fax: 86--311-80690567

Send your inquiry directly to us (0 / 3000)