· Magnets remove; detectors detect. A detector + diverter is the only layer that can catch non-ferrous and manganese steel tramp metal.
· Capture depth, not catalogue pull force, decides what a magnet gets: burden depth, belt speed, suspension height and how the metal presents itself.
· Every detector alarm costs production — sequencing the magnet upstream is what keeps the final gate trusted and switched on.
· A diverter flap converts alarms into a reject stream with near-zero downtime, trading a small volume of saleable material for uninterrupted crushing.
· Steel-cord belts, metal clip splices and magnetite ores all impose hard limits on detector performance and must be specified up front.
· One uncrushable object through a cone crusher routinely costs more than the installed price of a detector and diverter.
|
Criterion |
Self-Cleaning Overband Magnet |
Metal Detector + Diverter |
|
Detects |
Ferrous only (ferromagnetic) |
All metals: ferrous, non-ferrous, stainless, manganese steel |
|
Removes metal |
Yes — lifts it off the belt automatically |
No — signals; diverter or stop does the work |
|
Metal must be |
Exposed or near the burden surface |
Anywhere in the burden, including buried |
|
Blind spots |
Non-ferrous, manganese steel, deeply buried pieces |
Pieces below the aperture/speed sensitivity limit; steel-cord belts (conventional coils) |
|
Cost when it acts |
Almost none — no belt stop |
A reject volume (diverter) or a belt stop (no diverter) |
|
Main cost driver |
Field depth at the metal's position vs belt speed |
Aperture size, belt type, test discipline |
|
Best role |
Bulk ferrous reduction, first line of defence |
Final gate immediately before the crusher |
![]()
The order is not tradition — it follows from how the two devices fail.
The magnet handles volume; the detector handles exceptions. If an electromagnetic unit lifts an excavator tooth before the detector ever sees it, you avoid a belt stop for a piece that was going to be removed anyway. Fewer alarms means the detector stays trusted and switched on — and a detector that is switched off protects nothing. Field data from two-layer installations consistently shows nuisance-trip reductions of 60–80% once a properly sized magnet works the upstream belt.
The detector catches what the magnet physically cannot. Manganese steel hammers and liners, stainless fittings, non-ferrous scrap and deeply buried metal are not overlap — they are the detector's exclusive territory. That is why the detector belongs at the last practical point before the crusher: it is the final device that can still act before damage occurs.
The diverter is what makes the final gate economically viable. Without one, every alarm means a stopped belt, an operator walk-out, and a hunt for a bolt somewhere in hundreds of tonnes of product. With a flap diverter, the alarm becomes a split-second rejection of a small side stream. Plants pay for that reject volume in saleable material, but they stop paying in crushing downtime — and the arithmetic strongly favours the trade at any reasonable tonnage.
Position details decide whether the theory works:
· Mount the magnet on the upstream transfer where the burden is shallowest and most stable.
· Install the detector immediately upstream of the crusher feed, with enough free belt distance after the detector to accommodate the stopping distance calculated from belt speed and brake time.
· Keep the detector zone clean of steelwork, use non-metallic idlers where the manufacturer requires them, and record splice positions in the control logic.
· Give the magnet's discharge chute a locked, spill-proof collection point so captured iron cannot re-enter the product route.
· Add mechanical backstops — an impact bed under the loading point and clean transfer chutes — because a protection layer is not a substitute for a well-fed belt. A stable burden profile, supported by an appropriate Heavy-Duty Conveyor Impact Bed, makes both the magnet's capture window and the detector's test results meaningful.
![]()