TOGETHER HTL LTD is a very good company , I am very willing to cooperate with you, safe, efficient, professional, honest, happy! Thank you for providing me with stable service and products. -----EUROPAT

—— EUROPT INDUSTRIAL

I'm Online Chat Now
Company News
Suspended Magnetic Separators: Installation Is Where They Are Won or Lost
Latest company news about Suspended Magnetic Separators: Installation Is Where They Are Won or Lost

Two plants can buy the same overband magnet and get opposite results. One catches every bolt and bucket tooth in the stream; the other misses obvious steel and blames the supplier. The difference is almost never the magnet. It is where it hangs, how high, on what, and where the captured iron goes.

Here is the installation logic that separates the two, in the order a fitter would actually work through it.

✅ Decision one: position on the conveyor

🔧 The standard position is above the head pulley, with the pole face aimed at the falling material curtain. Material leaves the belt in free flight, iron has nothing holding it down, and captured scrap drops straight into a chute rather than riding round the pulley. This is where a Self-Cleaning Electromagnetic Separator does its best work above a crusher feed.

Mid-span mounting solves a different problem. When the head pulley is buried in a transfer tower or the plant wants protection at a specific drop point, the magnet rides over the loaded run instead. The penalty is bed depth: material sitting still against the belt buries iron deeper, so the magnet needs more field reach for the same capture rate.

Whichever position you choose, angle the pole face 10–15 degrees off horizontal. A perfectly level magnet collects captured iron on its face, and that steel beard grows until the gap closes and capture rates collapse.

✅ Decision two: working gap

📊 Height beats magnet size. Field strength falls off steeply with distance, so doubling the suspension height can cut capture depth to a fraction. Broad starting points for a first layout:

Belt Width (mm)

Typical Height Above Belt (mm)

650

250–300

800

300–350

1000

350–400

1200

400–450

1400+

450–500 plus a magnetic pulley as second stage

 

Then throw the catalogue away and measure your own plant. Bed depth under load is the number that matters, and the supplier's field-vs-distance curve for the specific unit is the only curve that counts. Confirm both with a capture test: drop bolts, nuts and a drill bit into the stream at rated belt speed, across several positions of the belt width. Twenty minutes of testing beats a year of arguing about whose spec was right.

✅ Decision three: suspension and stability

⚠️ A magnet that moves changes its own working gap with every lump of ore. Four-point suspension on chain or wire rope slings, adjusted level with turnbuckles, is the standard rig. Three checks keep it honest: re-torque the suspension bolts after the first 24 hours because new slings settle; confirm the frame clears the belt edge line even when the belt drifts; and keep a means of lowering the unit to waist height for inspection. If the conveyor wanders, fit a Conveyor Belt Tracker first — a rubbing pole face wears both the magnet and the belt.

2.Side view of an angled pole face throwing captured iron into a side chute

✅ Decision four: clearing the captured iron

🔧 Plain suspended magnets are cleaned by hand, which is fine at low tonnage and hopeless above a primary feed conveyor. Self-cleaning overband units carry captured iron to one side on an endless belt. Installation adds three jobs: fix the discharge side before ordering, because the drive housing changes the unit's balance; tension and track the cleaning belt properly during the first week; and inspect the belt cover weekly where it leaves the magnetic zone, because that line takes the wear on abrasive duty.

Discharge into a purpose-built chute with a skip or bin below. Iron that falls back onto the belt travels the circuit again and jams in places you cannot reach. On dusty duty, check the chute walls too — packed fines narrow the opening until scrap bridges across it and backs up onto the magnet face.

⚠️ Before the first switch-on

Electromagnetic units deserve a short commissioning list, run in order: verify rectifier output against the coil rating; megger the coil to earth and log the reading; confirm the over-temperature switch feeds an alarm someone actually watches; re-torque suspension hardware after the first loaded shift; run the capture test. Permanent units skip the electrical steps but keep the mechanical ones — and remember their field never switches off, so steel tools and ladders near the pole face behave badly during maintenance.

None of this costs extra when it is done at installation. All of it costs a crusher when it is not. A loose bolt through a jaw costs more than the magnet above it, and the downtime that follows runs into days. Tramp iron protection only protects when it is installed to a standard; the hardware is half the purchase, the rigging is the other half.

If you are sizing a unit now, start with conveyor profile photographs, measured bed depth and the duty the magnet must protect. The Electromagnetic Overband Separator range covers most mining feed conveyors once those three inputs are on the table.

Contact

Annie Lu

Email: annie.lu@huataogroup.com

WhatsApp / WeChat: +86 18032422676

Website: www.tufflexscreen.com

HTL Solutions manufactures suspended magnetic separators, overband units, magnetic pulleys and drums, with installation guidance for mining and mineral processing plants.

Hashtags

MagneticSeparator #OverbandMagnet #TrampIron #MiningMaintenance #ConveyorSystems #PlantEngineering #HTL

Pub Time : 2026-11-22 20:15:56 >> News list
Contact Details
TOGETHER HTL LTD

Contact Person: Mr. Maple

Tel: +86 17778255675

Fax: 86--311-80690567